Texas inspectors fill out TREC’s Property Inspection Report form (REI 7-6). Every item gets a box: I for inspected, NI for not inspected, NP for not present, and D for deficient. TREC defines deficient as a condition that adversely and materially affects how a system or component works, or that is a hazard to life, limb or property. The report is not a code inspection, and the form itself says a D doesn’t oblige anyone to make a repair. It tells you where to look closer.
“Cooling not performing” or a temperature differential outside 15–22°F
Under TREC’s rules the inspector measures the air going into the indoor unit and the air coming out. A difference outside 15 to 22 degrees Fahrenheit gets a D. A low number can come from a refrigerant or compressor problem; a high one often means too little air is moving across the coil, as with a clogged filter or a dirty coil. Very humid days also pull the number down. The reading is a symptom, not a diagnosis, so the cause has to be found before anyone can price the fix. See AC repair and the AC repair cost guide.
Water in the secondary drain pan, or drain line deficiencies
Most Houston air handlers sit in the attic over a pan. Water standing in the secondary (auxiliary) pan means the main drain line has backed up at some point. The rules also flag a primary drain that empties into a sewer vent and problems with the pan or its drain. Fix these early: an attic overflow is how a ceiling gets stained or soaked. See AC drain line cleaning.
Refrigerant line insulation, dirty coils, outdoor unit not level
The larger copper line between the outdoor and indoor units carries cold refrigerant and should be wrapped; bare pipe sweats and drips in Houston humidity. Dirty coils you can see, an outdoor unit that isn’t level or is boxed in by shrubs or a fence, and a blower that vibrates are also on TREC’s list. Several of these are handled in a maintenance visit.
Ducts: damaged, missing insulation, or no air at a register
Inspectors report damaged ducts, missing or damaged duct insulation, supply registers with no airflow, and filter, register and return problems. In an attic, a crushed or loose duct sends cooled air into the attic instead of the room. See duct repair.
Heating notes, and “not inspected” items
On a gas furnace the inspector reports gas leaks, flame problems, combustion air and venting deficiencies, and burners less than 18 inches above a garage floor unless the unit is listed for that. Inspectors are not required to check the heat exchanger, refrigerant charge, or whether a system is the right size, and they don’t have to run the A/C when it’s below 60°F outside. That’s why some reports mark cooling NI in winter. See furnace and heater repair and the furnace repair cost guide.
Water heater: relief valve, discharge pipe, pan and venting
The temperature and pressure relief valve is the heater’s safety valve. It gets a D when the valve or its discharge pipe is missing or visibly deficient, or when the valve fails a manual test. Other common notes: no drain pan where one is needed (attic and upstairs heaters especially), a pan drain that doesn’t end where it should, no cold-water shutoff, leaking or corroded fittings, and venting or combustion-air problems on gas units. Houston’s hard water also leaves sediment in tanks. See water heater repair and replacement, the water heater replacement cost guide and how to flush a water heater.
Water pressure over 80 PSI, or no expansion tank
Inspectors report the static water pressure and mark anything over 80 PSI as deficient, along with a missing pressure-reducing valve where pressure runs that high. Where a pressure-reducing valve, check valve or backflow preventer is installed, they also expect to see an expansion tank. High pressure wears on pipes, valves and the water heater. See water leak repair.
Gas: leaks, shutoffs, connectors, sediment traps, bonding
TREC lists noticeable gas leaks; no shutoff valve within six feet of an appliance; appliance connectors that are missing, longer than six feet, or run through a wall, floor or ceiling; missing sediment traps; and no visible bonding on the gas piping, including flexible stainless tubing (CSST). A gas leak comes before anything else on the report. Bonding is electrical work, which we don’t do; the gas piping items are plumbing. See gas line repair.
Drains, toilets, fixtures and pipe material
Slow drains, leaking traps, loose or running toilets and missing fixture shutoff valves show up on most reports. The inspector also lists the visible supply pipe material: gray plastic is the polybutylene used in some 1980s and early-1990s homes, and galvanized steel turns up in older houses (see repiping and the repiping cost guide). Sewer cleanouts aren’t part of the required inspection, and nobody can see a buried sewer line, so in an older home with slow drains a sewer camera look during the option period tells you far more. See sewer line repair and the sewer line repair cost guide.
Sources: TREC standards of practice, HVAC (22 TAC §535.230) · TREC standards of practice, plumbing (22 TAC §535.231) · TREC general provisions (22 TAC §535.227) · TREC Property Inspection Report form REI 7-6